An indicator is a rule of a time counter activation that is specified by proper conditions for starting, pausing, resetting, and  and stopping this counter. It also determines a the time limit for declaring SLA as breached and contains and contains time conditions of a Commitment commitment type implementation.

For example, based on your SLA agreement,you can create separate SLA separate SLA indicators for incidents that are having an impact from "Low" to " to Very High" and set a separate "separate Breach Time" value for them, based on your SLA agreement.

When an indicator starts, the system automatically generates an Indication, which is a time indication, a time counter that tracks current timings and time points of the target service level commitment.

Depending on your business needs, you may need different types of indicators:

  • standard – indicator creates indications that start or complete when specified conditions are met, or the duration ends.
    For example, the start time is when the task state changes to Assigned.
  • retrospective – indicator creates indications that count time based on the Date/Time column defined manually. Indications are created for records meeting specified conditions. To use this type of indicator, select the Defined by field option in the Indication start time and specify the field you need.
    For example, the start time is the value of the Opened at field, and the indication is created when the task state changes to Assigned.
Tip

Role required: service_level_manager.

Creating Indicator


To add a new Indicatornew indicator, please complete the following steps below:

  1. Navigate to the to Service Level Management → Indicator menu.
  2. Click New Click New and fill in the form.
  3. Click Save or Click Save or Save and Exit to  to apply changes.

The Indicator form fields 

Field

Required

Description

NameY
An

Specify the indicator name.

Note
Please do

Do not give the

similar

same name to indicators when creating them

against

for the same table; otherwise, they will not work

incorrectly

correctly if edited or deleted later.


AgreementNSpecify
an
an agreement
related
 related to this indicator containing tracking metrics.
Commitment
Type
typeN

Specify

a

the commitment type for this indicator. Available options:

  • Resolution Time
 -
  •  – the time it takes to resolve the issue (generally, the time from issue creation
until the "Completed" status update
  • to its state changed to Completed).
  • Response Time
 - the
  •  – the time it takes to process the issue in a non-automated
-
  • way (generally,
time
  • the from the issue creation
until the "
  • to its state changed to In Progress
" status update
  • ).
TableY

In this field, select a

task-based entity (Incidents, Problems, Requests) applied to define conditions of the Indicator attachment.

table to apply the Indicator conditions.

Note

After saving the form, the Table field becomes read-only. This is done:

  • to ensure the performance of indications for which start or breach time is specified by the appropriate field.
  • to keep the logical consistency and the correct indicator's work. 


InheritanceN

Select this checkbox if you are creating an indicator

on

for a parent table, and it is necessary to use it

against

for all

of the

child tables.

Info
titleExample
The

The Service Requests

table

 table can be

considered

thought of as a parent table, and

every

each extended table

extending it

is a single service request.

Turning

By enabling this attribute

on

, you can create

a single

one indicator

on

for a parent table which will affect every child table created.

Parent Dependency Column


ActiveN
In this field, you can specify a column in case you need to build "parent-child" dependencies between indicators. ActiveNSelect this checkbox on to make the indicator active or inactive.DurationY

The length of time the SLA runs before it is marked Breached.

Select this checkbox to make the indicator active or inactive.

Indication start time 

Anchor
indication start time
indication start time

N

Select one of two options:

  • Defined by condition – for standard indications. The standard indication start time is when a record meets the conditions defined in the Start Conditions tab.
  • Defined by field – for retrospective indications. Retrospective indication start time is based on the value retrieved from the Date/Time column specified in the Start time field. The record must also meet the conditions defined in the Start Conditions tab. Unlike the standard indication, the time when the conditions were met is ignored.
Start time fieldY

Define the column of the Date/Time type from which indications will be calculated, i.e., an indication retrieves the value for the start time from this column. 

Info

The field appears if the Defined by field option is selected in the Indication start time field.


Note
Note that a retrospective indication counts the value relevant at the time of indicator creation. If the value changes, indications will not be recalculated.


Indication breach timeN

Select one of two options:

  • Defined by duration – the indication breach time is based on the Duration value. The timing of the SLA breach also takes into account pause durations.
  • Defined by field – the breach time indication is based on the value retrieved from the Date/Time column specified in the Breach time field.
Note

After saving the form, the Indication breach time field becomes read-only.


Breach time fieldY

Define the column of the Date/Time type from which indications will be calculated, i.e., an indication that retrieves the value for the breach time from this column. After saving the form, the Breach time field field becomes read-only.

Info

The field appears if the Defined by field option is selected in the Indication breach time field.


Note
  • If the value of the referenced field is less than Start Time or Minimum duration, no indication will be created. 
  • If the value of the referenced field changes, the value in the related Indication record will be changed, and related fields will be recalculated.
  • If the value of the referenced field changes, and it is less than Start Time or less than Minimum duration, the indication will be canceled.


Business durationY

Set up a business time measure for the SLA to run before it is marked as Breached.

Info

The field changes to Minimum duration if the Defined by field option is selected in the Indication breach time field.


Note

Note that all day duration (not just business hours) according to the chosen schedule is taken into account. See the calculation samples below this table.


Minimum durationY

Set a minimum duration that restricts the creation of an indication and its existence. After saving the form, the Minimum duration field becomes read-only.

Info

The Minimum duration field appears if the Defined by field option is selected in the Indication breach time field.


Note

Please note that all day duration (not

only

just business hours)

 according

according to the chosen schedule is taken into account. See the calculation samples below this table.


ScheduleY
A

Select a working schedule

selected

from the list.

It determines the working hours that the system uses when calculating

an

the actual duration of

the

the Commitment

implementation

 implementation under certain conditions.

To configure this timeline, use

the 

the Schedules

 features

feature

TimezoneY
Determines

Determine an

indicator Timezone

indicator Timezone.

Note

Only active timezones are available to choose from.


Timezone
Source
sourceY

Select one of the available records from the drop-down list if you need to specify a special timezone bond.

The default value is

 

the Indicator

's

timezone. Available options:

Caller's
  • Indicator timezone
CI
  • Task location
's
  • timezone
Indicator
  • Caller's timezone
Task
  • CI location
's
  • timezone


Note
titleIndicator inheritance

Please keep in mind that if you create an inherited indicator on for a parent table, and after that a separate usual indicator on for a child table, the indications are to will be created only for a child table.

Also, when creating an inherited indicator against for a parent table, please keep in mind remember that the extended attributes from child tables will not be available there. See the brief illustration below:

On this picture, the table set is displayed:

  1. The parent table, attribute set is XX
  2. The child table 1, attribute set is XXYYY
  3. The child table 2, attribute set is XXYYYZZ

Considering the fact that the Because attribute inheritance is going top-down, the table attributes (such as fields) that extend parent table tables will be inaccessible on the lower level. Please note that when configuring conditions of your indicator, make all critical attributes accessible on the top level.

Duration calculations


Example 1.

Company A uses schedule "24x7", which means 24 working hours, 7 days a week, and around-the-clock shift-working, as an example. In this case, if work. If you enter "2" into the days field, this value is converted to 48 working hours or 2 working days. Nothing extraordinary.

Example 2.

Company B uses schedule "8x5" schedule , which means 8 working hours, 5 days a week, one of the most common working schedules. In this case, if If you enter "2" into the days field, this value is converted to 48 hours (because there are 24 hours in a day), which gives 6 working days.

Specifying indicator conditions


To specify the conditions you need to fill in the following tabs:

Field

Required

Description

Start ConditionsY

Establish conditions with the Condition Builder to

make

get the Indicator

start

started

The system uses the Table fields as transactional data to verify the conditions. When the transactional data changes, the system checks these conditions.

E.g.

,

for incidents, it is appropriate to use

 "

Impact

"

as a condition field with one of the possible values

- "

Low

"

,

"

Medium

"

,

"

High

"

,

"

Very High

"

.

The When to cancel

 setting

setting allows to establish a condition

for

to start cancellation by one of the options below:

      • Start conditions are not met
: the
      • – the system ignores the start conditions if it
doesn't
      • does not meet them
;
      • .
      • Cancel conditions are met

:
      •  this option enables additional conditions

setting The Condition Builder for cancel conditions appears only after selecting the 
      • that cancel start conditions when met.

In other words, if the system meets these cancel conditions, it ignores the start conditions.
To set cancel conditions, use Condition Builder below the When to cancel menu.
      •  

      • Do not cancel– start conditions are always verified.
Cancel Conditions Y

This option appears when the

Cancel conditions are met

 option.Never - start conditions are always verified

option is selected in the When to cancel field.

Define additional conditions to meet before the indicator cancels. If the system meets these cancel conditions, it ignores the start conditions.

Pause ConditionsN

Establish conditions with the Condition Builder to make the

Indicator

indicator pause. 

The system uses the Table fields as transactional data to verify the conditions. When the transactional data changes, the system checks these conditions.

E.g., for incidents, it is appropriate to use

 "

Impact

"

as a condition field with one of the possible values

- "

Low

"

,

"

Medium

"

,

"

High

"

,

"

Very High

"

.

The When to resume

 setting

setting allows to set a condition for pause resumption

by

using one of the options below:

      • Pause conditions are not met
: 
      • the system ignores the pause conditions if it
doesn't
      • does not meet them
;
      • .
      • Resume conditions are met

:
      •  this option enables additional conditions setting that resume

pause The Condition Builder for resume conditions appears only after selecting the 
      • paused conditions when met.

Resume ConditionsY

The field allows defining additional conditions to be met before the indicator has previously paused resumes. In other words, if the system meets these resume conditions, it ignores the pause conditions.

Resume conditions can be set with the Condition Builder below the When to resume menu.
Info

This option appears when the

Resume conditions are met

 option

option is selected in the When to resume field.


Complete Conditions
N
Y

Establish conditions with the Condition Builder to make the Indicator stop.

The system uses the Table fields as transactional data to verify the conditions. When the transactional data changes, the system checks these conditions.

Reset ConditionsN

Establish conditions with the Condition Builder to make the Indicator reset.

The system uses the Table fields as transactional data to verify the conditions. When the transactional data changes, the system checks these conditions.

Info

This field is unavailable for retrospective indications (the Defined by field option selected in the Indication start time field).



Note

If an indication is not on pause when the reset conditions have been met:

  • Pause time and its duration are reset.
  • Start time is set to the time reset conditions are triggered.
  • The breach time and original breach time are recalculated.
  • All specifications are recalculated according to the values defined.

If an indication is on pause when the reset conditions have been met:

  • Pause time are reset.
  • Start time and pause time are set to the time the reset conditions are triggered.
  • The breach time and original breach time are recalculated.
  • All specifications are recalculated according to the values defined.