Specify the indication recalculation period if there is more than one day left before breach time (this value is specified in the Breach time field of the Indication form).
If no value is specified, then the default value (7200 seconds) is applied. The minimum value is 60 seconds.
slm.calculation.period.before_breach_1_day
Integer
3600
Specify the indication recalculation period if there are from 6 hours to 1 day left before breach time (this value is specified in the Breach time field of the Indication form).
If no value is specified, then the default value (3600 seconds) is applied. The minimum value is 60 seconds.
slm.calculation.period.before_breach_6_hour
Integer
1800
Specify the indication recalculation period if there are from 2 to 6 hours left before breach time (this value is specified in the Breach time field of the Indication form).
If no value is specified, then the default value (1800 seconds) is applied. The minimum value is 60 seconds.
slm.calculation.period.before_breach_2_hour
Integer
600
Specify the indication recalculation period if there are from 30 minutes to 2 hours left before breach time (this value is specified in the Breach time field of the Indication form).
If no value is specified, then the default value (600 seconds) is applied. The minimum value is 60 seconds.
slm.calculation.period.before_breach_30_minutes
Integer
60
Specify the indication recalculation period in case if there are less than 30 minutes left before breach time (this value is specified in the Breach time field of the Indication form).
If no value is specified, then the default value (60 seconds) is applied. The minimum value is 60 seconds.